Materials
Material Options at a Glance
Screw Retained Zirconia Implant Crown | Screw Retained PFM Implant Crown | |
|---|---|---|
Core material | Zirconia, supplied in a range of strength / translucency grades | Metal framework (cast or milled) with layering porcelain |
Brands we work with | Domestic: Aierchang, Yurucheng · Imported: Wieland, Zenostar, 3M | Bego alloys |
Porcelain | Layering or monolithic zirconia, no separate porcelain | Ivoclar, Shofu, Noritake |
Best suited to | Esthetic zone, thin remaining wall space, single crowns | Posterior zones, higher occlusal load, cases wanting a long service history |
Minimum wall thickness | Anterior 0.5–1.5 mm · Posterior 0.8–2.0 mm | Framework plus porcelain must stay inside the same envelope — porcelain needs bulk |
Connector cross-section | Anterior 6–12 mm² · Posterior 9–16 mm² | Same limits apply |
How the screw channel is made | Milled through the zirconia; the Ti-base below it carries the screw | Cast or milled into the metal framework |
Mates to the implant via | Ti-base (bonded joint), or a zirconia/custom abutment | Custom or stock metal abutment (machined fit) |
Main technical watchpoint | Integrity of the zirconia-to-titanium bond | Framework fit, and porcelain margin behaviour under load |
Screw Retained Zirconia Implant Crown
Material grades. Zirconia is not one material. The yttria content in the zirconia powder determines how opaque or how translucent the sintered result is — higher yttria gives higher translucency and lower strength, lower yttria gives the reverse. Anterior cases in the esthetic zone usually call for a more translucent grade, because the restoration is being asked to transmit light. Posterior cases under heavy load usually call for a stronger, less translucent grade. If you tell us the position and the load, we will specify the grade; if you already have a brand in mind, we will work to it.
Brands. We work with domestic zirconia (Aierchang, Yurucheng) and imported zirconia (Wieland, Zenostar, 3M). You can name a specific brand and batch in your Rx and we will produce to it, or leave the selection to us against the case requirements.
Zirconia-to-titanium bonding. When a zirconia crown sits on a Ti-base, the two are joined by an adhesive bond, not by a screw — that joint is the weak link in an otherwise screw-retained assembly. We follow published MDP-based bonding protocols, which show that reliable bond strength requires both a proper surface treatment on the zirconia and a phosphate-functionalized monomer (MDP) in the adhesive system. Plain HF etching and a generic luting cement will not give the same result. This joint is inspected at QC before the case ships.
Wall thickness and connectors. These are the numbers we design to, and the numbers that decide whether a case is feasible at all:
Location | Minimum wall thickness | Connector cross-section |
|---|---|---|
Anterior | 0.5–1.5 mm | 6–12 mm² |
Posterior | 0.8–2.0 mm | 9–16 mm² |
Where a case sits inside the anterior range depends on how much enamel-like translucency you want versus how thin the wall can safely be. We check your prep design and available space during review and tell you before milling if the numbers do not work.
Try-in option. If you want to check emergence profile and fit before the final zirconia is processed, we can supply a pre-sintered zirconia try-in. Add it to the Rx — it extends the schedule and we will quote the revised timeline.
Screw Retained PFM Implant Crown
Metal framework. Bego alloys. The framework is what carries the load and what the screw channel is built into, so it is the part that has to be dimensionally exact.
Porcelain. Ivoclar, Shofu or Noritake layering porcelain, built and fired onto the metal framework.
When PFM still makes sense. A metal-ceramic implant crown is a long-established combination and it remains a reasonable choice in the posterior zone where esthetics are secondary and the load is significant. The framework can be made thinner in the metal than a solid zirconia wall of comparable strength, which matters when the interocclusal space is tight. The trade-off is esthetics: a metal collar at the margin will be visible unless it is placed palatally or lingually or the case allows full ceramic coverage.
Strength data — what we can and cannot give you. We do not have laboratory-verified flexural or fracture-load figures for our PFM frameworks. If you need a specific number for case planning or for a written justification, raise it before submission and we will tell you exactly what we can document and what we cannot. We are not going to quote a strength value we have not measured.
Abutment & Component Materials
The crown material is only half of the stack — what it attaches to matters as much:
- Ti-base (titanium base abutment): A prefabricated titanium component that carries a custom zirconia crown. The zirconia bonds to the Ti-base, then the whole assembly screws onto the implant. This is the most common configuration for a single crown in the esthetic zone.
- Angled screw channel (ASC): Redirects the screw path so the access hole clears occlusal contacts or a visible facial surface. Available angle depends on the component system — we confirm what your selected ASC permits before design.
- Multi-unit abutment (MUA): Titanium, used in multi-unit and full-arch cases. Gives a standardized platform height and a degree of angle correction.
- Custom abutment: Milled in titanium or zirconia to the emergence profile you want, when stock components cannot give you the position or the tissue contour the case needs.
Ti-bases, ASC, MUA, temporary cylinders, screws and the matching tools can be supplied with the case and are billed separately from the restoration.
Choosing Between Them
A practical way to read it:
- Anterior, high esthetic demand, limited space → zirconia on a Ti-base, more translucent grade, thin wall. Watch the bond joint.
- Posterior, heavy load, generous space → either works. Zirconia if you want a single-piece restoration; PFM if you want the thinnest possible framework.
- Tight interocclusal space → measure first. If the space will not clear the posterior thickness plus connector requirements in zirconia, tell us and we will tell you whether PFM or a cement-retained option is the realistic path.
- Unfavorable implant angulation putting the channel in a functional cusp → this is an abutment problem, not a material problem. ASC or a different retention method usually resolves it; we will raise it during review.
- Multi-unit or full-arch → the passive fit requirement across several implants dominates. See the QC section.
Material Traceability & Certificates
Every case can be documented back to the material used:
- Material batch number, brand, country of origin — available on request for zirconia blocks, PFM alloys, porcelain, and Ti-base components.
- Manufacturer's certificate of conformity — available per case on request. Note it in your submission or ask after delivery.
- How we track it: each case is logged with the lot used during fabrication, and the QC record references that lot number.
If you are working under a quality agreement, a hospital group protocol, or a specification review that requires documentation, ask for the certificates with the first case rather than retroactively.
Abutment Types & Implant System Compatibility
Implant system compatibility. We support most major systems including Straumann, Nobel Biocare, MIS and others. Interface matching depends entirely on your scan body registration — we need the scan body brand and model in the digital files, and we verify the resulting interface geometry during design review before anything is milled. Where we can, we use original manufacturer interfaces; where we supply a compatible part, we say so explicitly and it has to be one we can verify.
Screw-retained vs cement-retained. We are not dogmatic about it. Screw retention is the default because of retrievability and because it removes the cement cleanup variable. We will recommend cement retention if the implant angle is too buccal or lingual for the access channel to land somewhere acceptable, or if the esthetic requirement and the available space both point that way. That conversation happens at review, not as a standing policy.
Restoration Space & Prep Design
Screw-retained restorations need more vertical space than cement-retained ones, because the channel and the abutment interface both have to fit inside the same envelope as the crown.
We do not publish a single universal millimeter minimum, and you should be cautious of anyone who does. The requirement moves with the abutment type (Ti-base, ASC, MUA, custom), the implant system, the chosen screw, and the material — which is why the thickness figures sit in the Materials section above rather than here. We evaluate your scan, implant position and selected components together and confirm feasibility at review. If the space does not work, we will say so early and tell you what the alternatives are.
When to check this before you commit. Before you seat the final healing abutment or take the definitive impression. If you are unsure whether screw retention will fit, send a pre-operative scan or a CBCT slice and we will give you a preliminary read before you make the clinical decision.
Why Screw-Retained Design
Retrievability
You can unscrew the crown. That matters when you need access to the implant components for maintenance, when you want to adjust occlusion after the soft tissue has remodeled, or when a peri-implant problem has to be investigated. Research on screw-retained restorations notes that this reversibility is particularly valuable in posterior sites and in full-arch cases where long-term adjustability is the expectation rather than the exception.
No cement residue
Residual subgingival cement is a recognized contributor to peri-implant inflammation, and it is invisible once it is there. Screw retention removes the variable entirely — no cement margin, nothing to clear, nothing left behind.
The honest qualification: a 5-year randomized controlled trial comparing screw-retained and cement-retained implant crowns found no statistically significant difference in peri-implant tissue health between the two. Where cement is fully removed, the retention method is not what drives the tissue outcome. The decision is about retrievability, access-channel position and clinical workflow — not a claim that one method heals better.
The trade-off nobody mentions
Screw retention is not automatically better. The access channel occupies occlusal anatomy. If the implant angle puts the channel on a functional cusp, or on the facial surface in the esthetic zone, you are either accepting a compromised restoration, solving it with an ASC, or switching to cement. We fabricate all three and will tell you which one the anatomy supports.
Our In-House Workflow
No step leaves the building. The chain for a typical screw retained zirconia implant crown:
- Data receiving & evaluation — STL / PLY / OBJ files, photos and the prescription. We check implant position, scan body registration, soft tissue contour and available space.
- CAD design — the crown and emergence profile are designed from your scan data and the scan body. For a single implant crown, the emergence profile is designed against your healing abutment shape or gingival scan, and sent to you for approval before milling.
- 3D printing — physical models for verification or try-in frameworks where requested.
- CAM milling — the zirconia crown (or PFM framework) and any custom abutment components.
- Material processing — sintering, surface treatment, and for zirconia-on-Ti-base the bonding step under the manufacturer protocol.
- Porcelain build-out — for PFM and for layered zirconia.
- Polishing & finishing — occlusal and interproximal contacts and margins refined.
- Quality control — three-stage inspection (below).
- Packaging & shipment — the crown, the screw, and any Ti-base or tools are packed separately with traceability labels so small parts do not travel loose.
Lead time for complex implant and full-arch cases: 5–7 working days from approved design to shipment. That excludes design approval wait time, your reply time, international shipping and customs clearance. Chinese national holidays also extend the schedule — tell us your target date and we will tell you whether it is realistic.
Quality Control & Passive Fit
Three checkpoints before a restoration leaves:
- Post-milling — dimensional accuracy, margin integrity, internal fit.
- Post-finishing — occlusal contacts, interproximal contacts, contour, surface finish.
- Final pre-shipment — a senior QC technician reviews everything above plus the implant-specific items below.
Implant crown-specific checks:
- Interface accuracy — the abutment connection geometry must match the implant system's specification. Verified against the scan body data, not assumed.
- Screw channel alignment and clearance — the screw passes through without binding; the channel walls do not interfere with seating.
- Passive fit — test-seated on a lab analog or model. Full seating, no rocking, and removal does not take more force than the screw itself. On multi-unit cases this is the one that matters most: a crown that binds on one abutment preloads the others.
- Material joint integrity — for zirconia on a Ti-base, the bonded junction is inspected as its own item, not assumed from a successful press-fit.
- Screw and parts match — thread and head geometry verified against the abutment interface; any Ti-base or MUA traceable to the right system and batch.
First-pass yield on implant restorations is approximately 95%. Failed units are remade, not patched.
If a case does not fit clinically. We will ask for photos, the antagonist contact pattern, and whether the problem shows on the model or only intraorally — that distinction usually identifies the cause fast. Fabrication error (wrong interface, misaligned channel, margin defect) means a free remake. Changed requirements, or scan data we flagged and you elected to proceed with, means the remake is charged. Either way we agree the cause before starting.
Torque & Delivery Protocol
Torque. We work to the implant manufacturer's instructions for use. Typical final torque for single-crown abutment screws runs 20–35 Ncm depending on the system. The literature shows hand-tightening reaches roughly 11.5 Ncm, and a retighten after about 10 minutes raises preload — which is why the manufacturer's specified torque and retightening protocol are what actually matter at the chair.
We give you reference values for the system you specified, but the IFU is authoritative. If our reference and the current IFU disagree, the IFU wins.
Screws. A screw ships with each restoration. If you are reseating after a try-in or an adjustment, check the manufacturer's position on reuse — some systems specify single-use screws, others permit reuse if the threads are undamaged.
Over-torque. Over-torquing strips threads or fractures the screw. If you suspect it, stop and inspect the screw and the interface before going further. Replacement screws are available.
Fracture or loosening. If either happens, the investigation has to cover both sides — the restoration (passive fit, channel alignment) and the clinical factors (torque actually applied, occlusal load, bone integration). Where it turns out to be our side, we remake and cover the parts.
How to Submit a Case
What a single screw retained implant crown needs from you:
- Scan files — STL, PLY or OBJ. We work with 3Shape TRIOS, Medit, iTero, CEREC and Shining3D output.
- Implant system and scan body — brand, model, platform diameter, and the scan body brand and model used. This is what determines interface accuracy.
- Abutment configuration — Ti-base, ASC, MUA or custom. If you are unsure, describe the anatomy and we will recommend one.
- Material — zirconia or PFM. If zirconia, name a brand and grade if you have a preference; otherwise we select against the case.
- Emergence profile data — the healing abutment scanned or photographed, or a soft tissue scan showing the gingival contour. The subgingival profile is designed to match it.
- Shade — Vita shade tab reference or a digital shade match.
- Photos — retracted facial, occlusal, and lateral if available. These are used to check contour and contact design, not as a substitute for a shade reference.
- Case notes — occlusal scheme, contact tightness preference, anything anatomical we should know about.
Design approval. Single implant crowns go back to you for approval of the emergence profile and occlusal morphology before milling. Allow 24–48 hours for that review; it sits outside the fabrication lead time.
Original vs compatible parts. Where you provide or specify original manufacturer components, that is the default. If you would rather we supply them, we quote original and verified compatible options separately — original costs more and removes interface-match risk. We do not fit unverified third-party parts.
Regulatory Registrations
- FDA (U.S.) — establishment registration and device listing. The listed device scope covers custom crowns, bridges, inlays, veneers, custom implant abutments, implant suprastructures, dentures and temporary restorations. It does not cover dental implants themselves: we do not manufacture the fixture, only the prosthetic components that attach to it. You can look us up in the FDA public database.
- EU MDR — we operate as a Class IIa manufacturer under the Annex XIII custom-made device notification pathway. That is a self-declaration route for custom devices and does not involve a notified body certificate. Same prosthetic scope as above; excludes implant fixtures.
- MHRA (UK) — registration covering the same device scope for the UK market.
- ISO 13485 — quality management system certification for medical device manufacturing.
What that does and does not mean. These registrations confirm we operate as a legal manufacturer of custom dental prosthetics in those jurisdictions. They are not product-level "FDA approval" or "CE marking" in the certification sense — custom devices follow a different regulatory route from mass-produced ones, and we don't claim otherwise. If you need a copy of any registration for clinic credentialing or payer verification, ask and we'll provide it.
Service & Communication
- Dedicated case manager — one contact for intake, design coordination and delivery tracking.
- English throughout — case managers and technicians work in English; we can schedule video calls for complex planning or design review.
- Technical catalog — B2B catalog with material options, abutment compatibility charts and specs, available on request before your first case.
- Payment — bank wire or PayPal.
- We stay on our side of the relationship. This is a B2B lab-to-lab or lab-to-clinic arrangement. We do not contact or market to your end clients. If your purchasing policy needs it, we will sign a non-solicitation agreement.
Warranty & Remakes
Free when the cause is our fabrication error — wrong interface, emergence profile not matching the approved design, margin defects, screw channel misalignment. Shipping and implant components are excluded from the free remake.
Charged when the cause is changed requirements after design approval, or scan/model data we flagged during review and you chose to proceed with. We agree the cause before starting so there is no surprise invoice.
Components. Ti-bases, MUAs, custom abutments and screws are billed separately. If a remake is our error, we cover the restoration; we do not cover components unless the component itself was defective.
PFM framework re-veneering. We do not have a documented process for taking back a delivered PFM framework, stripping the porcelain and re-layering it. If you need a shade correction or porcelain adjustment on a PFM crown, ask before you send it — we will tell you what is actually feasible. More often than not a full remake is the more reliable result.
FAQ
Can you work with an implant system that isn't on your list? Yes. Send the implant brand, model, platform and scan body information. We confirm compatibility and source or verify the interface. Uncommon systems occasionally need a few extra days to confirm the geometry.
How do I know whether my case has room for screw retention? Send a pre-operative scan or CBCT with the tooth position, the esthetic priority and the interocclusal space. We will tell you whether the channel and the abutment interface clear, and what we would change if they do not.
Can I get a try-in stage? Yes, on request — bisque-bake for PFM, pre-sintered zirconia for monolithic. Note it on the Rx and we will quote the extended timeline.
What torque should I use? The manufacturer's IFU for the specific abutment screw. We supply reference values, but if our reference and the IFU differ, use the IFU. If you do not have the IFU to hand, most manufacturers publish it, and we can point you to it.
Can you match shade from a photo? We can try, but a Vita tab held next to the tooth in the same lighting is far more reliable than our reading of a photo's white balance. For a critical shade match, send a physical tab or a digital shade measurement.
What if the crown does not seat on the model and I cannot wait? We do not ship a restoration that failed model try-in unless you explicitly authorize it and accept responsibility for the clinical fit. If you choose to proceed, we document that the call was yours and a subsequent remake is charged.
Do you stock abutments or screws for emergency same-day shipment? No. Everything is custom-manufactured per your Rx, and we do not hold off-the-shelf stock for immediate dispatch. For an emergency component, go to the implant manufacturer's distributor — they normally hold stock for next-day delivery.
Can I have the same designer on all my cases? For ongoing relationships with consistent volume or a complex case pattern, we can assign a dedicated design technician. Talk it over with your case manager and we will confirm what is feasible against the workload.
Starting a Case
Send your files, photos and prescription to your case manager or our intake channel. We review submissions within 24 hours and come back with feasibility, timeline, any clarifications, and the quote.
- You send scans, photos and the Rx.
- We confirm feasibility, timeline and cost.
- We design and send you the emergence profile and occlusal design.
- You approve, or request changes.
- We fabricate, run QC, and ship.
- You seat it and torque to the IFU.
Factory and video tours are welcome — ask and we will schedule one.
This page describes our lab service for dental professionals. We are a B2B manufacturer, not a patient-facing provider.